MIS Implants Launches The Radically New V3 Dental Implant For Immediate Biological Benefits

"It's all in the shape", says Elad Ginat, Product Manager at MIS Implants. "The unique triangular shape of the coronal portion of the new V3 Implant enables a significant gain of bone and soft tissue volume where it matters most - so less titanium and more bone and soft tissue are available.”

Implant design can have a profound influence on the success of the osseointegration processes that unites bone to an implant surface. The unique triangular-shape of the V3 implant’s coronal portion has been designed to encourage bone regeneration and the gain of greater volume of bone in support of stable surrounding soft tissues for more esthetic restorations.

The triangular neck of the V3 provides solid anchorage at three points in the crestal zone while forming three compression-free gaps at the sides; between the implant and the osteotomy. This design is aimed at high primary stability and the reduction of bone compression and crestal bone resorption; favored conditions for increased osseointegration.

Elad explains that the compression-free gaps at the neck of the V3 encourage blot clot formation at the bone-implant interface, which promotes the initial scaffold-building process for bone growth. The gaps allow more space for blood pooling and the establishment of a stable blood clot. In this way, the V3 provides doctors with a more advantageous starting point; where greater volume of bone and soft tissue is achieved at the onset of implant placement.

The new V3 Implant is the result of an intensive two-year R&D process by MIS, along with their development partners: Prof. Nitzan Bichacho, Dr. Eric Van-Dooren and Dr. Yuval Jacoby. Elad mentions additional design features apart from the unique triangular neck shape, stating that the V3 is a high performance conical-connection implant with platform switching, a variable thread and self-tapping capability, micro-rings, a concave inter-thread for maximum BIC, and a flat apex supporting immediate placement engagement.

“Doctors can enjoy all these impressive V3 design benefits without having to learn new protocols” says Elad. He further explains that V3 protocols are the same as with most other dental implants doctors are already familiar with, and that a dedicated V3 surgical kit makes procedures especially simple, safe and accurate; resulting in ease of placement for the dentist and shorter recovery time for patients.

MIS describes the V3 as a multi-use implant, suitable for a wide range of surgical scenarios and ideal in anterior regions, or where space and bone may be limited and good esthetic outcomes are essential. The new V3 design aims to provide surgical specialists and GP’s alike with optimum flexibly in implant planning and placement for a restorative-driven approach.

“MIS is immensely proud of our innovative position in the global implants industry, which has led to the development of the unique V3 Implant System,” concludes Elad. “It’s a widely anticipated evolutionary next-step in dental implant performance, designed for the benefit doctors and their patients the world over.”

ABOUT MIS: Established in 1995, MIS Implants Technologies Ltd. is a global leader in the development and production of advanced products and innovative solutions aimed to simplify implant dentistry. MIS offers a comprehensive range of cutting-edge dental implants, superstructures, tools and kits, as well as extensive solutions for oral restoration and health.


III International Implantology Days in Baden-BadenThe symposium, which will be held May 22-24, it's a meeting with leading experts in the field of implantology. The theme of the conference will be the guidelines for interdisciplinary clinical issues that doctors are faced with in their daily work with patients. A comprehensive list of the world's top experts guarantees a high level of lectures which will be based on the work of the specialized literature, researches and interesting clinical experience.

The event will take place in Baden-Baden (Germany), which offers exciting tourist and cultural attractions and charms with stunning views. Symposium supports the activities of a charitable organization working for children's education in Tanzania.

Check for the congress plan


THE ESSENCE OF BEAUTY is the first conference of the new cycle prestigious events dedicated to contemporary trends and solutions used in dentistry, organized by MIS Poland.

A this year's conference is discussion about new faces of implantology in combination with workshops of innovative techniques applied in contemporary dentistry these are elements which they will cause, that together we will appoint the latest trend in this field of science.

More information and registration:



4bone logo

The name 4BONE® represents an entire family of quality regenerative biomaterial solutions consisting of bovine, porcine and synthetic based products that offer solutions for a wide range of bone regeneration procedures. The 4BONE line includes a Bovine Bone Matrix, Synthetic Bone Substitute, Bonding Graft Material, Resorbable Conforming Barrier Membrane, Resorbable Collagen Barrier Membrane and Plug and Tape-Wound Dressings.

Flexibility is a key feature of the new 4BONE® product range recently introduced by MIS Implants. Products can be mixed together in various configurations to achieve more flexible treatment solutions, i.e. resorption time and types of bone matrix required. Products are packed in varying weights and volumes, for simple and easy delivery directly to the surgical site. MIS regenerative products also mix readily with other biomaterial brands.

MIS best serves our customers by providing a wide range of quality bone grafting materials, membranes and accessories to answer almost any clinical scenario. Quality equipment and design control processes assure high standards of sterilization and safety for all 4Bone products; making it safer and making it simple. The 4BONE line has recently been launched in the USA and will soon be available in other countries pending approvals.

The 4Bone line includes the following products:


Granulat wykonany z nieorganicznej macierzy kości wołowej

4Bone XBM

An anorganic bovine bone mineral matrix for use in bone regeneration procedures, and recommended for use as a bone void filler or augmentation material in periodontal defects and dental implant procedures.

It is produced by removal of all organic components from bovine bone, leaving the natural mineral component for use as an osteoconductive material for bone regeneration. Due to its natural structure, 4BONE XBM is physically and chemically comparable to the mineralized matrix of human bone. The trabecular architecture with interconnecting macro and micro pores allows for the optimal ingrowth of new vascularity and bone at the graft site and maximizes the potential for angiogenesis.

Membrana z kolagenu wołowego typu I

4Bone RCB

A resorbable Conforming Barrier Membrane engineered from highly purified Type I bovine collagen. It is a fully resorbable and adaptable cell occlusive barrier used in guided tissue regeneration and guided bone regeneration procedures in the areas of dental implants, bone defects and ridge augmentation.

Upon hydration, the barrier membrane easily adapts and adheres to all surgical sites and promotes healing of bone and soft tissue. RCB can be easily trimmed and does not deform or adhere to itself or instruments when hydrated. The optimal mechanical properties and high tensile strength of RCB allows for easy placement and adaptability in ridge augmentation procedures, due to its ability to naturally conform to the site where it is placed.

4Bone RSB Membrana z kolagenu wołowego - utrzymująca kształt

4Bone RSB

A bioresorbable, cell occlusive membrane engineered from highly purified bovine collagen. It is indicated for use as a barrier membrane in guided tissue regeneration and guided bone regeneration procedures in the area of dental implants, bone defects and ridge augmentations.

Due to its optimal initial rigidity and defined stability, the RSB Membrane is the product of choice to prevent soft tissue ingrowth during healing in defects that lack bony wall support. Its semi-permeable properties permit the exchange of essential nutrients for healing, while the porosity qualities effectively hinder epithelial down growth; preventing gingiva connective tissue cell migration into the treated site. Optimal resorption time allows for sustained function during the healing process.

4Bone Stożki kolagenowe

4Bone Płatki kolagenowe

4BONE PLUG & TAPE Wound Dressings

 Used following oral surgical procedures to control bleeding, stabilize blood clots and aid in wound healing. They are engineered from highly purified cross-linked type I bovine collagen with an optimal structure and thickness to allow the absorption of both fluid and blood at the defect site.

These sterile dental wound dressings are engineered from bovine Type I collagen. They protect the oral wound bed and controlling bleeding due the hemostatic properties of collagen fibers. Both the PLUG and TAPE are fully resorbed within 10-14 days.

M4 Implant

The new features of the M4 are:

- A Flat cutting apex: Allowing final adjustments during placement procedures.

- Surface: The surface roughness and micro-morphology is a achieved by a combination of sand blasting and acid etching. MIS’ established surface technology has provided millions of patients and clinicians with excellent osseointegration results and long lasting clinical success.

- Cylindrical shape with V-shaped threads: For mild bone compression while achieving maximum initial and long term stability.

- Internal hexagon: MIS M4 implants feature an internal hex. connection. This well established connection assures proper abutment seating, anti-rotational engagement, resistance to lateral forces, excellent esthetic results and more.


MIS is pleased to announce the release of a new full M4 Surgical Kit (MK-0016). The new M4 Kit contains the complete range of drills and tools required for a full implant placement procedure. The new kit features a convenient tool layout and a protective cover with an easy opening mechanism for quicker access.


© 2010 - 2015 MIS Poland. All rights reserved.

Odwiedzin od 2011-12-01: 202057